Our patented approach to measuring velocity makes OFS 2000 series the air/gas/steam flow monitoring system of choice in:

  • CEM
  • Power plants
  • Refineries: flare lines, steam and air flare assisted
  • Chemical processing
  • Incinerators
  • Air/gas handling systems

OFS 2000 unique scintillometry measurement technique offers all our systems the same basic advantages:

Non-Intrusive 

No direct contact with flow media. Measurement is immune to the effects of temperature, gas density, moisture content, particulate count, or pressure. If OFS 2000 can detect the turbulence-induced light fluctuations with even a fraction of the light, it can accurately measure the flow velocity. It is, in this sense, a “pure” measurement.

No Calibration Required

Using scintillation as a basis of measurement means the all-digital / DSP-based OFS 2000 systems require no calibration – ever. Our patented process is supported with over 20 million hours of observation data, and certified by NIST (National Institute of Standards.) Automatic calibration check along with continuous self-test diagnostics are built-in for user security.

Full-Path Averaging 

OFS 2000 provides a dynamic velocity measurement of the passage of gas or air through a light beam averaged directly across the entire volume. Scintillation through the entire path is detected, analyzed, calculated, and reported - a much more representative measurement than single point or slanted path.

Measures Volumetric Flow 

Along with superior accuracy, OFS 2000 can also be configured with the ability to accept smart temperature and pressure sensor current loop data to calculate and report volumetric flow or mass flow in addition to velocity.

Measurement Reporting By 

  • 4-20mA Current Loop
  •  RS 232/485
  • ModBus RTU
  • Network/Fiber Optic Connectivity

Measurement Not Affected By 

  • Distance
  • Pressure
  • Temperature
  • Gas Density
  • Moisture
  • Opacity

Measurement Not Dependent On  

  • Differential pressure
  • Design DP
  • Beta ratio
  • Temperature
  • Gas composition
  • Humidity 
  •  Speed of sound

Flexible Installation  

OFS can install in tight spaces with minimum space requirements of 2 upstream / 1 downstream diameters. No re-piping needed. Installation is to standard ANSI pattern 4” pipe flange. OFS can be installed on live process pipes using hot tap procedure and gate valves for isolation. No shutdown needed.

Flexible Communication 

All systems are equipped with analog current loop / digital data outputs, and can be configured with Serial port, Limited Distance Modem, and Fiber Optic Interface for any type of WAN or LAN.

No moving parts

OFS 2000 is essentially maintenance-free, save for window cleaning. OFS internal monitoring alerts the user if window cleaning is required. (Typically only semi-annually (if then) on the dirtiest stack and duct applications.)

Assures Compliance

All OFS 2000 sensors meet or exceed requirements set by the Environmental Protection Agency, and California’s South Coast Air Quality Management District. 


EPA Method 14
EPA MACT RSR 40 CFR 63.670
EPA 40 CFR part 60 & 75
EPA 40 CFR part 60 sub part J & Ja
SCAQMD rule 1118

For further information: contact your local representative/reseller; contact us by phone; or simply send us an email 

Optical Scientific, Inc.
2 Metropolitan Court
Suite 6 
Gaithersburg, MD 20878 USA


Telf: +01 301 963 3630
Fax: +01 301 948 4674

E-mail: infofpt@opticalscientific.com

opticalscientific.com